BANTE 900p EC910 pH mV/ORP/ION Conductivity TDS Salinity DO Temperatur

Rp17.500.000

Bante900P pH/Conductivity/DO Meter

Multiparameter water quality meter, containing 8 measurement modes, stores up to 500 data.

pH Mode:
• Multiparameter water quality meter is equipped with a backlit LCD display.
• 1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers.
• Automatic electrode diagnosis shows the pH slope and offset.

ORP Mode:
• 1 point offset calibration allows adjusting the displayed value to a known standard.
• Relative and absolute millivolt modes ensure the reliable ORP measurements.

Ion Concentration Mode:
• 2 to 5 points calibration, including the 8 concentration points can be selected.
• Direct ion concentration readout simplifies the measurement process.
• Automatic electrode diagnosis shows the calibration points and slopes.
• Selectable concentration units (ppm, mg/L, mol/L, mmol/L) and ionic valency.

Conductivity/TDS/Salinity/Resistivity Modes:
• 1 to 5 points calibration with automatic recognition for conductivity standards.
• Selectable cell constant (K=0.1/1/10), reference temperature (20/25°C), TDS factor, linear
and pure water compensations, seawater and practical salinity measurement modes.

Dissolved Oxygen Mode:
• 1 or 2 points calibration using the air-saturated water or zero oxygen solution.
• Salinity and barometric pressure compensations eliminate the measurement error.

Other Features:
• Automatic temperature compensation ensures accurate readings over the entire range.
• Auto-Read function senses and locks the measurement endpoint.
• Calibration due alarm prompts user to calibrate the meter regularly.
• Auto-Power Off effectively conserves battery life.
• Setup menu allows setting the number of calibration points, stability criteria, temperature
unit, date and time, etc.
• Reset function automatically resumes all settings back to the factory defaults.
• Expanded memory stores or recalls up to 500 data sets.
• USB communication interface is easy to transfer data to PC.
• Multi-mode power scheme (batteries, power adapter and USB port) ensures that using the
meter smoothly.

SpecificationsOrdering InfoOptional AccessoriesPackaging

   Model Bante900P

pH   

Range : -2.000 to 20.000 pH

Resolution : 0.001 / 0.01 / 0.1 pH, selectable

Accuracy : ±0.002 pH

Calibration Points : 1 to 5 points

pH Buffer Options : USA / NIST / DIN / 2 custom buffers

Range : -1999.9 to 1999.9 mV

Resolution : 0.1 / 1 mV, selectable

Accuracy : ±0.2 mV

Calibration Points 1 point

Measurement Modes Relative / Absolute mV

 

   Ion Concentration   

Range : 0.00 to 19999 (depending on the range of ISE)

Resolution : 0.001, 0.01, 0.1, 1, automatic

Accuracy : ±0.5% F.S. (monovalent), ±1% F.S. (divalent)

Calibration Points : 2 to 5 points

Calibration Solutions : 0.001 / 0.01 / 0.1 / 1 / 10 / 100 / 1000 / 10000

Measurement Units  : ppm, mg/L, mol/L, mmol/L

 

   Conductivity

Range : 0 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm

Resolution : 0.001, 0.01, 0.1, 1, automatic

Accuracy : ±0.5% F.S.

Calibration Points : 1 to 5 points

Calibration Solutions : 10 µS / 84 µS / 1413 µS / 12.88 mS / 111.8 mS

Temperature Coefficient : 0.0 to 10.0%/°C

Pure Water Compensation : Yes

Reference Temperature : 20 / 25°C

Cell Constant  : K=0.1 / 1 / 10 / Custom

 

TDS 

Range : 0 to 10.00, 100.0, 1000 ppm, 10.00, 200.0 ppt

Resolution: 0.01, 0.1, 1, automatic

Accuracy : ±1% F.S.

TDS Conversion Factor : 0.1 to 1.0 (default 0.5)

 

Salinity        

Range : 0.00 to 80.00 ppt / 0.00 to 42.00 psu

Resolution : 0.01

Accuracy : ±1% F.S.

 

   Resistivity   

Range : 0.00 to 20.00 MΩ

Resolution : 0.01

Accuracy : ±1% F.S.

 

   Dissolved Oxygen  

Range : 0.00 to 20.00 mg/L / 0.0 to 200.0 % saturation

Resolution : 0.01 / 0.1, selectable

Accuracy : ±0.2 mg/L / ±2.0 %

Calibration Points : 1 or 2 points

Pressure Correction  60.0 to 112.5 kPa / 450 to 850 mmHg, manual

Salinity Correction   0.0 to 50.0 g/L, manual

 

   Temperature

Range : 0 to 105°C / 32 to 221°F

Resolution : 0.1°C/°F

Accuracy : ±0.5°C / ±0.9°F

Offset Calibration 1 point

Calibration Range : Reading ±10°C/°F

 

   Other Specifications

Temperature Compensation : 0 to 100°C / 32 to 212°F, manual or automatic

Hold Function : Manual / Auto-read measurement endpoint

Stability Criteria : Low / High

Calibration Due Alarm :  1 to 31 days or off

Auto-Power Off  : 10 / 20 / 30 minutes after last key pressed

Memory : Stores up to 500 data sets

Output : USB communication interface

Connector : BNC, 6-pin mini-DIN, 3.5 mm jack socket

Display : Custom LCD (80 × 60 mm)

Power Supply : 3 × 1.5V AA batteries or 5V DC power adapter

Battery Life  Approximately 150 hours without backlight

Environmental Conditions : 0 to 50°C / 32 to 122°F, relative humidity < 80%

Dimensions : 170 × 85 × 30 mm

Weight : 300 g

Weight 3000 g

There are no reviews yet.

Be the first to review “BANTE 900p EC910 pH mV/ORP/ION Conductivity TDS Salinity DO Temperatur”

Your email address will not be published. Required fields are marked *